There are currently no reviews for this product. This product might be new but if you decide to purchase this item, please come back and be the first to write a review!
What is the difference between a rechargeable and non-rechargeable fire extinguisher?
It is important to understand the difference between rechargeable fire extinguishers and non-rechargeable fire extinguishers. Non-rechargeable fire extinguishers are intended for one time use only. If you use your non-rechargeable fire extinguisher even once, you must replace it. It will not be effective in fighting a fire. Never test a fire extinguisher by using it. Once used, it will gradually lose pressure and will not be fully charged for use in an emergency. Rechargeable fire extinguishers are intended to be recharged once they are used, or when it loses pressure over time. Once a year or according to your local fire codes, rechargeable fire extinguishers in business or commercial applications should be serviced by a certified fire equipment dealer, in accordance with the service manual and as identified on the fire extinguisher label. If it is discharged, a rechargeable fire extinguisher must be refilled by a certified fire equipment dealer regardless of how much of the contents were used.
The gauge on my unused fire extinguisher is in the red. What should I do?
If a fire extinguisher pressure gauge shows that the charge is in the red zone, a disposable fire extinguisher should be replaced. If it is a First Alert disposable fire extinguisher that is still under warranty, contact Consumer Affairs at 1-800-323-9005 for warranty service. Please note that you must completely empty the unit before shipping, turn the extinguisher upside down and the agent will run out. Since the unit is no longer pressurized, no shipping precautions are necessary. If any of your rechargeable fire extinguishers show a pressure gauge reading in the red, they should be taken to a local fire extinguisher service business to be recharged and serviced if necessary. If it is a First Alert rechargeable fire extinguisher that is still under warranty, contact Consumer Affairs at 1-800-323-9005. Please Note: If you trigger-test a First Alert fire extinguisher, your warranty will be void.
What is a fire extinguisher life expectancy?
Non-rechargeable fire extinguishers generally have a 6 year life expectancy. Keep in mind life expectancy depends on a number of factors. A fire extinguisher should be tested weekly according to the user's manual. As long as the pointer is in the green area or the pin indicator pops back up when pushed, the extinguisher is properly pressurized and ready to use.
My fire extinguisher appears to be almost empty. Will it still work?
For rechargeable fire extinguishers, as long as the needle is in the green, the fire extinguisher is fully pressurized. If you have discharged a non-rechargeable fire extinguisher, it is recommended that you replace the unit.
What do I do if the pin does not pop back up on my unused fire extinguisher?
If you have an unused disposable fire extinguisher and the pin does not pop back up, the unit should be replaced. If it is a First Alert Fire Extinguisher and it is still under warranty, contact Consumer Affairs at 1-800-323-9005 for warranty service. Please note: if you have trigger-test your First Alert disposable fire extinguisher, your warranty will be void.
First Alert Rechargeable Heavy Duty Plus Fire Extinguisher
The First Alert PRO5 Rechargeable Heavy Duty Plus Fire Extinguisher is effective against the most common household fires: wood, paper, fabric, flammable liquid fires and live electrical equipment fires. The PRO5 uses a heavy duty metal head that's designed to exceed demanding needs. This heavy duty plus fire extinguisher can also be recharged by a certified professional when in use, ensuring lasting protection. The First Alert PRO5 Rechargeable Fire Extinguisher includes a heavy duty mounting bracket and strap to keep the unit secure. PRO5 Fire Extinguishers meet UL standards.
Portable and Ideal for All Types of Fires
The PRO5 extinguisher is portable and can be recharged by a certified professional when used. It is designed to fight wood, paper, fabric, flammable liquid, and electrical fires.
Durable Construction
The Rechargeable Heavy Duty Plus Fire Extinguisher is made of a durable metal head that is designed to meet demanding needs. The PRO5 also features a metal pull pin with a safety seal that deters accidental discharge and discourages tampering. The Heavy Duty Plus Fire Extinguisher includes a secure mounting bracket and strap for placement of the extinguisher. The color coded gauge is easy-to-read, corrosion-resistant, and provides accurate measurement.
Easy to Use
This fire extinguisher includes easy to follow, 4-step instructions right on extinguisher. The label is chemical resistant and water proof, so you do not have to worry about it deteriorating.
Class A, B & C Fire Extinguisher
First Alert Class A, B & C Fire Extinguishers are designed to put out three types of fires (combustible fires, flammable fires and electrical fires). These fire extinguishers can put out fires caused by ordinary combustible materials such as firewood, plastic, cloth and paper. They're also capable of putting out fires caused by flammable liquids and combustible gas. These fires are capable of spreading extremely fast and can be attributed to gasoline, grease, oil and paints. The First Alert Rechargeable Heavy Duty Plus Extinguisher can also put out electrical fires. Electrical fires are commonly caused by electrical equipment, paneling, wiring and circuit breakers.