  • Hardwired + 10-Year Backup: Powered by 120V household electricity with a sealed 10-year lithium battery backup during power outages.
  • Advanced Fire Detection: Sensing Plus® multi-criteria photoelectric technology accurately identifies fast-flaming and slow-smoldering fires.
  • System Interconnectivity: Connects with up to 24 compatible USI hardwired alarms to sound simultaneously throughout your home.
  • Clear Voice Alerts: Spoken notifications clearly announce fire hazards and maintenance reminders like battery replacement.
  • Fewer False Alarms: Superior resistance against cooking steam and everyday humidity minimizes nuisance alarms.
  • Hassle-Free Installation: Includes a pre-stripped quick-connect wiring harness and mounting bracket for simple setup.

Hardwire Smoke & Fire Alarm with 10-Year Battery Backup Product Description

The Universal Security Instruments Hardwired Smoke Alarm with 10-Year Battery Backup delivers reliable, continuous home fire protection. Running on 120V household wiring, this high-performance hardwired smoke detector includes a sealed lithium 10 year battery backup to keep monitoring your home during power outages. Built-in Sensing Plus Multi-Criteria Detection allows this 10 year smoke alarm to rapidly spot fast-flaming and slow-smoldering fires, while smart photoelectric tech prevents false alarms from kitchen smoke or bathroom steam.

For complete home safety, this interconnected hardwired smoke detector connects directly with compatible alarms so every unit sounds at once when danger is detected. Spoken voice alerts state the exact situation, helping you clearly distinguish between an active fire emergency and a maintenance warning. Installing this code compliant hardwired smoke detector with battery backup gives you total peace of mind and zero annual battery changes, making it the ideal 10 year smoke detector upgrade for any property.


Key Features & Benefits

  • 120V Hardwired + 10-Year Backup: Runs on household AC power with a sealed 10-year lithium battery during outages.
  • Multi-Criteria Smoke Sensing: Sensing Plus® technology detects both fast-flaming and slow-smoldering fires.
  • Whole-Home Interconnect: Links with up to 24 USI devices to trigger all alarms simultaneously.
  • Voice Alerts: Clear verbal warnings announce fire emergencies and system status updates.
  • Smart Nuisance Resistance: Filters out everyday cooking smoke and steam to prevent false alarms.
  • Easy Quick-Connect Setup: Includes a pre-stripped wiring harness and bracket for fast installation.

Industry Standards & Compliance

This alarm is certified to meet strict residential building requirements:

  • ETL Listed: Tested to UL 217 (9th Edition) safety standards for single and multiple station smoke alarms.
  • NFPA Compliant: Meets NFPA 72 requirements for hardwired residential fire detection systems.
  • Federal Housing Standards: Fully compliant with FHA, HUD, and CSFM (California State Fire Marshal) regulations.
  • New Construction Approved: Perfect for new builds, retrofits, and replacing existing 120V hardwired smoke detectors.

(Note: Connects directly to standard 120V household wiring. This combo alarm can replace existing hardwired units easily.

Where to Install This Alarm

For full residential safety compliance, this independent alarm can be mounted to either the ceiling or the wall.

  • Recommended Placement: Inside every individual bedroom/sleeping room, directly outside of sleeping areas (within 21 feet of any bedroom door), and on every single level of your home, including basements.
  • Ceiling Mounting: Install at least 4 inches (10 cm) away from any side wall.
  • Wall Mounting: Position the top edge of the alarm between 4 inches (10 cm) minimum and 12 inches (30.5 cm) maximum below the ceiling line.

Installation Locations to Avoid

To ensure long-term accuracy and prevent false alarms, do not place this device:

  • Within 6 feet of commercial or residential cooking appliances.
  • Within 10 feet of high-humidity zones like bathrooms, dishwashers, laundry rooms, or sinks.
  • Directly near air returns, ceiling fans, or drafty windows/doors that could blow smoke away from the sensor.
  • In dusty, dirty, or insect-infested spaces (like uninsulated garages or attics).
  • Near fluorescent light fixtures, where electronic noise can interfere with the circuitry.
Can this hardwired smoke detector be interconnected with other alarms in my home?
Yes. This hardwired smoke detector supports multi-station interconnectivity with up to 24 compatible devices (including up to 18 smoke alarms). When wired into your home’s electrical circuit, triggering one alarm causes all connected hardwired smoke alarms throughout the residence to sound simultaneously.
Does this smoke alarm help prevent false triggers from cooking?
Yes. Designed to meet UL 217 (9th Edition) safety standards, its multi-criteria sensor technology is specifically calibrated to distinguish between actual fire hazards and non-emergency steam or routine cooking vapors, significantly reducing nuisance false alarms.
How do I replace an existing hardwired alarm with this model?
Turn off power at the main circuit breaker, remove your old mounting bracket, and attach the included quick-connect wiring harness (line, neutral, and interconnect wires) to your electrical junction box. Once secured to the mounting base, the sealed 10-year battery backup activates automatically.
How do the voice alerts work on this hardwired smoke detector?
This hardwired smoke detector includes built-in voice warnings that clearly announce emergency hazards rather than relying solely on standard beeping patterns. During a fire event, the unit explicitly speaks the nature of the emergency alongside the 85 dB horn, and it provides spoken updates when the unit reaches its end of service life or needs attention.
What happens to this hardwired smoke alarm during a home power outage?
If your home loses main AC power, the hardwired smoke alarm with 10-year battery backup seamlessly transitions to its sealed internal lithium power battery. Your home remains continuously protected against smoke and fire threats throughout electrical blackouts without interrupting interconnection or requiring manual adjustments.
Product Details

new sensing plus smoke alarms

Product Specs
UPC:
017801703139
MPN:
USI/SM/HW10YR/P
Category:
Smoke Alarms
Product Manuals

If you are interested in ordering a large quantity of items you may qualify for volume pricing discounts. Volume Discount Pricing is a great way for customers to save big on large, bulk orders of most items available in our store. Please send a bulk order request to our friendly sales staff so they may create a quote and provide personal service for your order! You will receive a response within 1-2 business days and our office hours are Monday through Friday, 8am-5pm CST.

We make it as easy as possible to ensure you get the lowest prices available:
  • Let us know what products & the quantities you are interested in.
  • Get a detailed quote from a dedicated sales rep.
  • Our warehouse ships directly to you.
  • You enjoy the savings & are now a preferred customer.
Send A Request Now
Direct From Warehouse Pricing bulk purchase, wholesale pricing

Customer Reviews

This item does not have any reviews yet.
0 $0.00
Top